In 87 days of NetApp RAID data, a disk was 2x slower than its peers in 0.22% of drive hours, but a RAID group had a slow drive in 1.54% of hours

NetApp field data (Hao et al., FAST 2016): disks and SSDs were 2x slower than their RAID group median for 0.22% and 0.58% of drive hours, but groups had a slow drive for 1.54% and 2.23% of hours. Dean and Barroso (CACM 2013) give the fan-out arithmetic; Gunawi et al. (FAST 2018) and Lu et al. (FAST 2023) are cross-checks from other fleets.

Download CSV24 rows · 7 columns · CSV

File /data/datasets/storage-tail-slowdowns-raid-fanout.csv · JSON metadata · All datasets · Human-readable note on hesela.com

Method

The figures are copied from the USENIX PDFs of Hao et al. (FAST 2016), Gunawi et al. (FAST 2018), and Lu et al. (FAST 2023), and from the author PDF of Dean and Barroso (Communications of the ACM, February 2013); no chart was read. Hao et al. compare each drive's hourly average latency to the median of its RAID group and call an hour slow when the ratio is at least 2; a tail hour is a RAID hour with at least one slow drive. Rows marked derived by us are our division of printed counts or our recomputation of the printed formula 1 minus (1 minus p) to the power n. The four sources come from different organizations and fleets: NetApp customers, Google, a set of operator reports, and Alibaba. Hao et al. and Gunawi et al. share an author, so they are not fully independent of each other. Sources opened for this table: The Tail at Store: A Revelation from Millions of Hours of Disk and SSD Deployments, Hao, Soundararajan, Kenchammana-Hosekote, Chien, and Gunawi, USENIX FAST 2016 (USENIX PDF, abstract and sections 1 and 4); The Tail at Scale, Dean and Barroso, Communications of the ACM, February 2013 (author PDF); Fail-Slow at Scale: Evidence of Hardware Performance Faults in Large Production Systems, Gunawi et al., USENIX FAST 2018 (USENIX PDF, sections 1 and 3); Perseus: A Fail-Slow Detection Framework for Cloud Storage Systems, Lu et al., USENIX FAST 2023 (USENIX PDF, abstract).

Limits

Table

24 rows, the same rows as the CSV. Value low and value high are the printed range ends, or a single printed value in the high column. Units are in the unit column. Sources are the pages opened on 2026-10-12.
MeasureValue lowValue highUnitScopeNoteCitation
Data disks studiednot stated458482drivesNetApp field RAID groups, 87 days on averageTable 1 of the paper; 38,029 disk RAID groups.hao-fast16-pdf
Data SSDs studiednot stated4069drivesSame study572 SSD RAID groups.hao-fast16-pdf
Disk drive hours observednot stated857183442drive hoursSame studyThe abstract rounds this to 857 million.hao-fast16-pdf
SSD drive hours observednot stated7481055drive hoursSame studyThe abstract rounds this to 7 million.hao-fast16-pdf
Disk hours at least 2x slower than the RAID group mediannot stated0.22percent of drive hoursDisks, slowdown ratio of 2 or moreHourly average latency against the median of the group.hao-fast16-pdf
SSD hours at least 2x slower than the RAID group mediannot stated0.58percent of drive hoursSSDs, same rulehao-fast16-pdf
Slow hours with a 1.5x threshold0.691.27percent of drive hoursDisks (0.69) and SSDs (1.27)A tighter threshold than the 2x used elsewhere.hao-fast16-pdf
RAID hours with at least one slow disknot stated1.54percent of RAID hoursDisk RAID groups, 2x thresholdCalled tail hours by the authors.hao-fast16-pdf
RAID hours with at least one slow SSDnot stated2.23percent of RAID hoursSSD RAID groups, 2x thresholdhao-fast16-pdf
RAID hours with a slow drive, 1.5x threshold4.64.8percent of RAID hoursDisks (4.6) and SSDs (4.8)hao-fast16-pdf
Slow disks per RAID hour with a slow disknot stated1.70slow drives per tail hourDerived by us: 1,885,804 slow disk hours divided by 1,109,514 tail hoursBoth counts are in Table 1; more than one slow drive tends to appear together.hao-fast16-pdf
Slow SSDs per RAID hour with a slow SSDnot stated1.80slow drives per tail hourDerived by us: 43,016 divided by 23,964Same method for SSDs.hao-fast16-pdf
Slow drives that stay slow for more than an hour3540percent of slow drivesSSDs (35) and disks (40)hao-fast16-pdf
Drives with at least one slowdown2629percent of drivesDisks (26) and SSDs (29)Over the study window, not a yearly rate.hao-fast16-pdf
Disk tail hours if the longest tail were cutnot stated0.6percent of RAID hoursDisk RAID groups, tail-tolerant RAID estimateDown from 1.5; 0.3 if the two longest were cut. Assumes slowdowns are independent.hao-fast16-pdf
Requests slow when each server is slow 1 time in 100, fan-out 100not stated63percent of requestsIdealized service, Dean and BarrosoEquals 1 minus 0.99 to the power 100, which we recomputed as 63.4.dean-barroso-cacm13-pdf
Requests slow when each server is slow 1 time in 10,000, 2,000 serversnot stated18percent of requestsIdealized service, Dean and BarrosoThe article says almost one in five; we recomputed 18.1.dean-barroso-cacm13-pdf
99th percentile latency of one random leaf requestnot stated10millisecondsA large fan-out Google service, measured at the rootdean-barroso-cacm13-pdf
99th percentile latency until all leaf requests finishnot stated140millisecondsSame serviceWaiting for the slowest 5% accounts for about half of this, per the article.dean-barroso-cacm13-pdf
SSD read latency increase from garbage collectionnot stated100timesSolid-state storage with modest write activityStated in the article as a factor of 100 without a dataset.dean-barroso-cacm13-pdf
Cut in 99.9th percentile read latency from tied requestsnot stated38percentBigTable benchmark on a mostly idle cluster, tied request after 1 msReads sent to a second replica; 32% with a concurrent sort job.dean-barroso-cacm13-pdf
Fail-slow hardware incident reports studiednot stated101reportsGunawi et al., collected from large-scale clustersA convenience sample, not a rate.gunawi-fast18-pdf
Incidents that took months to pinpointnot stated17percent of incidentsSame reports; 45% have an unknown timegunawi-fast18-pdf
Fail-slow drives found among drives monitorednot stated0.12percent of drivesDerived by us: 304 of 248,000 drives in 10 months at Alibaba (Lu et al.)A sustained fail-slow detector, not an hourly threshold, so not comparable with the NetApp hours.lu-fast23-pdf

Columns

measure (string)
The quantity as the source names it, or our derived quantity.
value_low (number)
Lower end of a printed range. Empty when the source prints a single value.
value_high (number)
Single printed value, or the upper end of a range.
unit (string)
Unit of the value columns: drives, drive hours, percent, milliseconds, times, reports.
scope (string)
Population and window the value applies to; 'Derived by us' marks our arithmetic.
note (string)
What the value is not, or the source wording behind it.
citation_id (string)
Id of the opened source in the citations list.

License

Small derived table of figures printed in Hao et al. (FAST 2016), Dean and Barroso (CACM 2013), Gunawi et al. (FAST 2018), and Lu et al. (FAST 2023), plus our labelled arithmetic, with credit. Not a Creative Commons license. The papers remain with their authors or publishers. This file is not a copy of the papers and not the data.

Sources

  1. The Tail at Store: A Revelation from Millions of Hours of Disk and SSD Deployments, Hao, Soundararajan, Kenchammana-Hosekote, Chien, and Gunawi, USENIX FAST 2016 (USENIX PDF, abstract and sections 1 and 4) (accessed 2026-10-12)
  2. The Tail at Scale, Dean and Barroso, Communications of the ACM, February 2013 (author PDF) (accessed 2026-10-12)
  3. Fail-Slow at Scale: Evidence of Hardware Performance Faults in Large Production Systems, Gunawi et al., USENIX FAST 2018 (USENIX PDF, sections 1 and 3) (accessed 2026-10-12)
  4. Perseus: A Fail-Slow Detection Framework for Cloud Storage Systems, Lu et al., USENIX FAST 2023 (USENIX PDF, abstract) (accessed 2026-10-12)