# An energy interval is not an endpoint-only thermal-age interval

Hesela research supplement, 18 November 2026. Existing scope #6382 / PR #6385.
**Evidence: a mathematical deduction and synthetic computation, not device measurements.**

## Main result

For a known temperature history, a fixed but uncertain activation energy can
produce the smallest reference-equivalent exposure *inside* its allowed range.
Checking only the two energy endpoints can therefore exclude admissible model
outputs. The largest exposure does occur at an endpoint.

This is not a new NAND mechanism. It is a consequence of applying the existing
Arrhenius clock consistently to a history that crosses the chosen reference
temperature. It joins the existing retention-clock and thermal-age-bounds work,
without replacing either or adding a duplicate glossary identity.

## What the primary sources establish

[NIST's Arrhenius description](https://www.itl.nist.gov/div898/handbook/apr/section1/apr151.htm)
makes activation energy dependent on mechanism and material. Its increasing
acceleration statement compares a hotter temperature to a colder one; it does
not establish monotonicity of a mixed history relative to an intermediate
reference. Our calculation uses exact SI constants and 273.15 for Celsius
conversion, not the handbook's rounded conversion.

[HeatWatch](https://people.inf.ethz.ch/~omutlu/pub/heatwatch-3D-nand-errors-and-self-recovery_hpca18.pdf),
section 4.2, printed pages 9-10, reports a fitted energy of 1.04 eV with
95% interval 1.01-1.08 eV for its tested chips. The fitting temperatures are
20-70 C and wear levels 1,000-10,000 P/E cycles. The paper explicitly treats
one fixed energy across conditions as a simplifying choice. Section 5.2
separately describes keeping temperature and dwell-history information.

**Our 0.1-1 eV sensitivity range is hypothetical.** It is not that paper's
confidence interval, a fit to an SSD population, or a claim that 0 C lies in
its fitted temperature range. We do not reproduce its full model or its
device measurements. NIST's [physical-acceleration discussion](https://www.itl.nist.gov/div898/handbook/apr/section1/apr14.htm)
also requires preserving the relevant mechanism; an algebraically valid time
conversion does not establish that physical premise.

## Model and proof

For known segment durations h_i > 0, segment temperatures T_i and reference R
in kelvin, define:

```text
c_i = (1/R - 1/T_i) / k                 [1/eV]
Q(E) = sum_i h_i exp(c_i E)             [seconds]
Q'(E) = sum_i h_i c_i exp(c_i E)        [seconds/eV]
Q''(E) = sum_i h_i c_i^2 exp(c_i E)     [seconds/eV^2]
```

The unknown E is **one common, fixed parameter** for the whole history.
Since Q'' >= 0, Q is convex in energy for any positive temperatures,
independently of the temperature-convexity condition in the earlier packet.
It is strictly convex unless every T_i equals R.

For a closed interval [E_lo, E_hi]:

1. The maximum is max(Q(E_lo), Q(E_hi)).
2. If Q'(E_lo) >= 0, the minimum is Q(E_lo).
3. If Q'(E_hi) <= 0, the minimum is Q(E_hi).
4. Otherwise the unique interior zero of Q' gives the minimum.

If all temperatures exceed R, all c_i are positive and Q increases.
If all are below R, Q decreases. Crossing R is necessary, but not sufficient,
for an interior minimum: the interval still has to bracket the zero.

For two plateaus with c_cold < 0 < c_hot, the unconstrained minimizer is:

```text
E_star = log[-h_cold c_cold / (h_hot c_hot)] / (c_hot - c_cold)
```

Clamp it to the allowed interval. This analytic expression is the independent
oracle for the bisection implementation. A third plateau tests the general
derivative search rather than only this special case.

## A reproducible counterexample

Synthetic history: 77,760 seconds at 0 C and 8,640 seconds at 55 C,
with reference 25 C and one common E in [0.1, 1] eV. The total is one day;
90% of it is cold and 10% hot. The values below come from energy_results.json.

| Calculation | Energy (eV) | Equivalent days at 25 C |
| --- | --- | --- |
| Left endpoint | 0.1 | 0.773016383 |
| Interior minimum | 0.308731678 | 0.599628194 |
| Right endpoint / maximum | 1 | 3.535842305 |

The endpoint-only range [0.773016383, 3.535842305] omits possible exposures.
The actual model range is approximately [0.599628194, 3.535842305].
Its missed lower end is **28.915950%**:
(endpoint-only minimum / true model minimum - 1) times 100.

This percentage measures an error in this deliberately constructed numerical
procedure, not an error rate, lifetime reduction, probability or population
estimate. No statistical confidence level attaches to the chosen energy range.

## Do not confuse known-history and summary uncertainty

The earlier packet knows only duration, support [L,U] and time mean mu,
while holding E fixed. This supplement knows the complete piecewise-constant
history, but allows E to vary. They optimize over different admissible sets.

If *both* the history and E are unknown, the earlier sharp bounds can still
be combined, provided the multiplier is convex in temperature for **every**
admissible energy. In the positive-energy case it suffices that E_lo/k >= 2U.
A zero-energy singleton and a single-temperature support are degenerate cases.

For fixed E, the lower witness is constant mu and the upper witness mixes
L and U. The constant-mu lower expression is monotone (or constant) in E.
The upper endpoint-mixture expression is convex in E. Therefore, under that
uniform temperature-convexity condition, the joint lower and upper extremes
can be found from the two energy endpoints of these *summary-bound functions*.

For the same one-day support 0-55 C, time mean 5.5 C, reference 25 C and
E in [0.1,1] eV, this yields approximately **0.065627932 to 3.535842305 days**.
Constant 5.5 C at E=1 attains the lower; the stated cold/hot mixture at E=1
attains the upper. The broader interval reflects missing history, not a
contradiction with the known-history result. A regression test checks these
witnesses and 1,001 energy values against the joint envelope.

## Two additional interpretation traps

**Separate segment extrema change the parameter model.** Choosing a different
E to minimize each segment permits an energy that changes with time.
Summing those minima is generally below the minimum with one common E;
summing maxima is generally above the common-E maximum. These can be loose
outer bounds, but are not the attainable interval for a common calibration.
Tests show both inequalities strictly for the counterexample.

**The reference is part of the result.** Moving R changes the energy minimizer.
At a fixed E, changing the reference multiplies Q by an E-dependent factor.
An uncertain-energy range therefore cannot be converted using one universal
scale factor. This does not make physical data loss depend on the chosen
reference: Q is a normalized model clock, not a failure probability.

## Reproduce and validate

Python standard library only. Run in this directory:

```sh
python3 -B energy_generate.py
python3 -B -m unittest -v test_model test_energy_envelope
python3 -B -O -m unittest -q test_model test_energy_envelope
python3 -B verify_float.py
```

The supplement generates eight cases, including all-hot, all-cold, flat,
fixed-energy, mixed endpoint and three-plateau controls. Its tests compare
the general optimizer with a closed-form solution, the original integrator,
a finite-difference derivative and an independent binary64 calculation over
125 histories at 101 energies each. Boundary, invalid-input, duration,
ordering, subdivision, common-parameter and reference controls are included.

The solver evaluates Decimal arithmetic at 60 digits; generation checks
extrema and minimizers at 100 digits. Tests also exercise 30 and 200 digits.
The minimizer bracket uses a 10^(-digits+12) eV stopping tolerance.
Published values have 18 significant digits and are rounded estimates,
**not directed-rounding certified enclosures**. Rounded bracket endpoints
can print identically. Input guardrails are the earlier packet's computational
limits, not safe device operating ranges.

No temperature log, calibration dataset, sensor mapping or NAND experiment
was collected. No refresh, changing mechanism, cycling-dependent energy or
recovery-history model is implemented. Real-world application requires those
assumptions and the original telemetry acceptance checks to be justified.

## Integration recommendation

Add the short sensitivity warning from ARTICLE_INSERTION.md beside the
existing retention-clock material. Publish this proof, code and generated
data through the existing DEV research-asset process first. Retain both
types of uncertainty explicitly. Reuse effective-retention-time and
activation-energy records; no new term, article or benchmark is needed.