Degaussing
Degaussing applies a strong magnetic field matched to a medium's coercivity to disrupt recorded magnetization, sanitizing suitable tape and disk media but not flash.
NIST SP 800-88 Rev. 2 treats degaussing as a possible purge technique, not an approved destroy technique. The field must match the medium's coercivity, its ability to resist demagnetization, and too weak a field can leave data recoverable. Servo damage can make a drive inoperable without sanitizing it, flash is not sanitized at all, and many existing degaussers lack the force for higher-coercivity recording. [2]
Degausser ratings in oersteds must equal or exceed those of the media. In a 2021 evaluated list degaussers carried 3,000 Oe for tape and 5,000 Oe for longitudinal and perpendicular disks, against 3,000 Oe for LTO-6 and LTO-7, 2,800 Oe for LTO-4 and LTO-5, 1,850 Oe for DLT and 520 Oe for a legacy mainframe cartridge. Disk ratings rose from 2,200 Oe for drives of 1995 or earlier to 5,000 Oe for 2004-2005. [4]
Evaluation accepts only degaussers producing at least 30,000 gauss throughout the chamber, enough for most commercial media in 2020 though heat- and microwave-assisted recording will need more, and requires 40 devices per hour for electromagnetic and 100 for permanent-magnet units. [3]
For classified hard disks degaussing must be followed by physically deforming the platters, making it a step before destruction rather than a replacement. [4]
Relations
- related
- Magnetic tape storage, Data sanitization, Purge sanitization, Destroy sanitization, Sanitization verification, Sanitization validation, Hard disk drive (HDD), LTO (Linear Tape-Open), Cryptographic erase, Clear sanitization
Advantages
- Suitable media are purged without relying on the host data interface. [2]
Limitations
- Loss of device usability is not proof of successful sanitization. [2]
- Listed equipment is not guaranteed to keep performing and should be re-tested with an approved field verification device. [4]
Citations
- NIST SP 800-88 Rev. 2 (2025). Guidelines for Media Sanitization, section 3.1.2.
- NSA/CSS Requirements for Magnetic Degaussers, 2021, sections 3, 4.5 and 4.6.
- NSA/CSS Evaluated Products List for Magnetic Degaussers, October 2021.
Further reading
Sources & caveats
- The NSA/CSS evaluation documents govern classified media of one government; their requirements are not general rules.
- Ratings come from the October 2021 edition of the evaluated list; later editions may differ.