efmplus · also EFM+, DVD 8-to-16 modulation

EFMPlus

EFMPlus is a stateful recording modulation code that maps each input byte to sixteen channel-code bits while controlling transition spacing and low-frequency content.

The 1995 design replaces EFM's fourteen-bit word plus three merging bits with a rate-8/16 code. Relative to 8/17, the coding-rate gain is 17/16 - 1 = 6.25%, not the total DVD-versus-CD capacity gain. [1] [3]

DVD-ROM uses four encoding states. The (2,10) constraint counts zeros between transition indicators; after NRZI conversion the corresponding data runs span 3T to 11T, where T is one channel-clock period. Synchronization has separate rules. [2]

A synthetic 16-bit word, 1001001001001001, has legal internal spacing but fails when concatenated with itself: the boundary contains adjacent ones. An encoder must control the join, not just each word in isolation. This is a generic constraint example, not a table lookup. [4]

Modulation shapes the recorded signal; it does not replace the outer error-correcting code. Code rate also excludes framing and error-correction overhead. [3]

Relations

related
Run-length limited (RLL) encoding, Digital sum value, DVD ECC block

Citations

  1. Immink. EFMPlus: The Coding Format of the MultiMedia Compact Disc. IEEE TCE 41(3), 491-497 (1995). (accessed 2026-11-23)
  2. ECMA-267, 2nd edition (1999), clauses 4.4, 20-22 and Annex G. (accessed 2026-11-23)
  3. Immink, Siegel and Wolf. Codes for Digital Recorders. IEEE TIT 44(6), 2260-2299 (1998), sections III-A and IV-D. (accessed 2026-11-23)
  4. Hesela - finite RLL boundary and NRZI balance examples, generated results. (accessed 2026-11-23)

Further reading

  1. Hesela - executable signal model (JavaScript, CC0). (accessed 2026-11-23)
  2. Hesela - exhaustive small-word regression tests (Node.js, CC0). (accessed 2026-11-23)
Sources & caveats
  • The 1995 abstract establishes the proposal and code rate; encoding details were checked in ECMA-267 clauses 20-22 and Annex G, not inferred from the abstract.
  • The finite example tests a run constraint, not the DVD lookup tables, synchronization, decoder or error-correction system. No media measurements are reported.

JSON: /data/terms/efmplus.json

Published by Hesela team · Updated

Report a correction · Editorial standards · Reuse guidance

Cite this page
Hesela team. EFMPlus. Hesela. 2026-11-23. https://hesela.dev/terms/efmplus/