NVMe Unexpected Power Losses

NVMe Unexpected Power Losses is the SMART / Health Information log counter of main-power losses that meet the specification's incomplete-shutdown conditions.

Related Observatory article: NVMe Unexpected Power Losses on hesela.com

Formerly named Unsafe Shutdowns, the field counts power loss before the controller reports ready to be powered off (CSTS.SHST = 10b), plus specified out-of-band Admin-command cases in which Ignore Shutdown permits media access during or after shutdown processing. NVMe Base 2.3 places it at bytes 144 through 159. Its definition is not limited to a missing CC.SHN notification; readiness and media shutdown state matter. [2]

Relations

related
nvme-smart-log, nvme-media-data-integrity-errors, nvme-error-information-log-entries

Limitations

Citations

  1. Changes in NVM Express Specifications (August 2024), section 1.2.23.1, p. 15: rename and revised counting conditions (accessed 2026-10-14)
  2. NVM Express Base Specification 2.3, section 5.2.12.1.3, Figure 210, p. 216: Unexpected Power Losses (accessed 2026-10-14)