RAID 10
RAID 10 combines replicated data copies with striping across storage members.
Conventional RAID 1+0 uses fixed mirror groups; with two members per group, every group needs a current, readable survivor. Any single member may fail, but two failures in one pair remove both copies of its data. [4] Linux MD also supports near, far and offset layouts and odd member counts, so copy placement must be checked. [2]
Hesela's fixed-pair enumeration counts failure combinations, not observed reliability or repair timing. [3] Ratios of counted subsets describe conditional probabilities only when same-size failure sets are equally likely; failure-count timing and member placement require separate evidence. [3]
RAID 0+1 mirrors complete stripe sets instead of striping over fixed mirrors. The same disk count does not make these nesting orders interchangeable. [4]
Relations
- related
- RAID, Mirroring (storage), Striping (storage), Mirror set, Failure domain, Degraded array, RAID 01
Limitations
- A count of failed disks does not identify whether every required mirror retains a usable copy. [3]
Citations
- mdadm md(4): RAID1 and RAID10 layout (revision e5a1d3e)
- Hesela: RAID 10 mirror topology and exact failure-set counts
- SNIA Swordfish 1.2.4a: RAIDType placement definitions